We’ve upgraded Alisouq for a faster, smoother experience
We’ve upgraded Alisouq for a faster, smoother experience
SKU: HDM3L40S400A3X0B2
1552.94
(incl. VAT)
loading...
The Himel - Molded case circuit breaker HDM3L - 400S/4P(A) - mag-therm - 400 A is a type of electrical protection device that is used to protect the electrical circuit from excessive current, which can cause overload or short circuit. It has a rated current of 400 A and a rated breaking capacity of 70 kA. It is a thermal-magnetic circuit breaker, which means that it uses both thermal and magnetic elements to trip the circuit in the event of an overload or short circuit. The thermal element trips the circuit when the current exceeds the rated current for a certain period of time, and the magnetic element trips the circuit when the current exceeds a certain threshold.
This circuit breaker is also equipped with earth leakage protection, which means that it can also protect the circuit from earth leakage faults. Earth leakage faults occur when there is a current flowing between the live and earth conductors. This can be caused by a faulty appliance or a damaged cable. The earth leakage protection in this circuit breaker will trip the circuit if the earth leakage current exceeds a certain threshold.
Rated current: 400 A
Rated breaking capacity: 70 kA
Thermal-magnetic tripping
Earth leakage protection
Suitable for use in a wide range of applications
Protects electrical circuits from overload and short circuit
Reliable and effective
Good choice for a variety of applications
Easy to install and maintain
Long service life
The Himel - Molded case circuit breaker HDM3L - 400S/4P(A) - mag-therm - 400 A is a type of electrical protection device that is used to protect the electrical circuit from excessive current, which can cause overload or short circuit. It has a rated current of 400 A and a rated breaking capacity of 70 kA. It is a thermal-magnetic circuit breaker, which means that it uses both thermal and magnetic elements to trip the circuit in the event of an overload or short circuit. The thermal element trips the circuit when the current exceeds the rated current for a certain period of time, and the magnetic element trips the circuit when the current exceeds a certain threshold.
This circuit breaker is also equipped with earth leakage protection, which means that it can also protect the circuit from earth leakage faults. Earth leakage faults occur when there is a current flowing between the live and earth conductors. This can be caused by a faulty appliance or a damaged cable. The earth leakage protection in this circuit breaker will trip the circuit if the earth leakage current exceeds a certain threshold.