We’ve upgraded Alisouq for a faster, smoother experience
We’ve upgraded Alisouq for a faster, smoother experience
SKU: HDM3L12S050A3X0B2
652.61
(incl. VAT)
loading...
The Himel - Molded case circuit breaker HDM3L - 125S/4P(A) - mag-therm - 50A - 1/3/5 - delay is a type of electrical protection device that is used to protect the electrical circuit from excessive current, which can cause overload or short circuit. It is a molded case circuit breaker (MCCB), which means that it is a self-contained unit with all of the necessary components enclosed in a molded case. The breaker has a rating of 50A, which means that it can safely carry a current of up to 50A. It also has a thermal-magnetic trip unit, which means that it can be tripped by either a thermal overload or a magnetic short circuit. The breaker has a delay function, which means that it will not trip immediately when a fault occurs. This delay function helps to prevent nuisance tripping.
The breaker is rated for a voltage of 400/415V and a frequency of 50/60Hz. It has a breaking capacity of 50kA and a short-time withstand current of 8kA. The breaker is also equipped with a number of safety features, including an earth leakage trip, an overload trip, and a short circuit trip.
Rated for 50A
Thermal-magnetic trip unit
Delay function
Voltage rating of 400/415V
Frequency rating of 50/60Hz
Breaking capacity of 50kA
Short-time withstand current of 8kA
Dimensions of 257mm x 150mm x 107.5mm
Weight of 2.5kg
DIN rail mounting
Protects electrical circuits from overload and short circuit
Reliable and effective
Good choice for a variety of applications
Easy to install and maintain
Long service life
The Himel - Molded case circuit breaker HDM3L - 125S/4P(A) - mag-therm - 50A - 1/3/5 - delay is a type of electrical protection device that is used to protect the electrical circuit from excessive current, which can cause overload or short circuit. It is a molded case circuit breaker (MCCB), which means that it is a self-contained unit with all of the necessary components enclosed in a molded case. The breaker has a rating of 50A, which means that it can safely carry a current of up to 50A. It also has a thermal-magnetic trip unit, which means that it can be tripped by either a thermal overload or a magnetic short circuit. The breaker has a delay function, which means that it will not trip immediately when a fault occurs. This delay function helps to prevent nuisance tripping.
The breaker is rated for a voltage of 400/415V and a frequency of 50/60Hz. It has a breaking capacity of 50kA and a short-time withstand current of 8kA. The breaker is also equipped with a number of safety features, including an earth leakage trip, an overload trip, and a short circuit trip.