SKU: HDM3L12F050A3X0B2
674.8
(incl. VAT)
loading...
The molded case circuit breaker (MCCB) HDM3L - 125F/4P(A) - mag-therm - 50A - 1/3/5 - delay is a thermal-magnetic circuit breaker with a rated current of 50 A and four poles. It has a delayed trip feature, which means that the breaker will not trip immediately if the current in the circuit exceeds the set level. Instead, it will wait a short period of time before tripping. This delay is designed to prevent the breaker from tripping due to a temporary overload, such as a surge in current caused by a motor starting.
The delay time for the HDM3L - 125F/4P(A) - mag-therm - 50A - 1/3/5 - delay breaker can be adjusted from 0.1 to 0.5 seconds. This allows you to customize the breaker to the specific needs of your application.
The breaker has a thermal-magnetic trip unit, which means that it can trip due to either overload or short circuit. The thermal element in the trip unit responds to the increase in current, while the magnetic element responds to the rate of increase in current. This combination of elements provides a reliable and sensitive trip mechanism.
Rated current: 50 A
Frame size: 125AF
Number of poles: 4
Trip unit: Thermal-magnetic
Breaking capacity: 50 kA
Rated voltage: 400/415 V
Frequency: 50/60 Hz
Insulation voltage: 800 V
Impulse withstand voltage: 8 kV
Mechanical life: 20,000 cycles
Electrical life: 7,500 cycles
Prevents the breaker from tripping due to a temporary overload.
Provides more time for the circuit to be shut down safely.
Helps to protect sensitive equipment from damage.
The molded case circuit breaker (MCCB) HDM3L - 125F/4P(A) - mag-therm - 50A - 1/3/5 - delay is a thermal-magnetic circuit breaker with a rated current of 50 A and four poles. It has a delayed trip feature, which means that the breaker will not trip immediately if the current in the circuit exceeds the set level. Instead, it will wait a short period of time before tripping. This delay is designed to prevent the breaker from tripping due to a temporary overload, such as a surge in current caused by a motor starting.
The delay time for the HDM3L - 125F/4P(A) - mag-therm - 50A - 1/3/5 - delay breaker can be adjusted from 0.1 to 0.5 seconds. This allows you to customize the breaker to the specific needs of your application.
The breaker has a thermal-magnetic trip unit, which means that it can trip due to either overload or short circuit. The thermal element in the trip unit responds to the increase in current, while the magnetic element responds to the rate of increase in current. This combination of elements provides a reliable and sensitive trip mechanism.