We’ve upgraded Alisouq for a faster, smoother experience
We’ve upgraded Alisouq for a faster, smoother experience
SKU: HDM3L12F050A3X0B0
654.46
(incl. VAT)
loading...
HDM3L-125F/4P(A)-mag-therm-50A is a thermal-magnetic circuit breaker with a rated current of 50 A and 4 poles. It is designed to protect electrical circuits from overload and short circuit. The breaker has a breaking capacity of 125 kA and a rated voltage of 400 V. It is also equipped with an earth leakage protection function and has a delay time of 1/3/5 seconds.
The delay time is the amount of time it takes for the breaker to trip after the current exceeds the rated current. The different delay times are used to protect different types of equipment and electrical circuits. For example, a short delay time is used to protect equipment that can withstand a brief overload, while a long delay time is used to protect equipment that is more sensitive to overload.
The HDM3L-125F/4P(A)-mag-therm-50A is a reliable and safe way to protect electrical circuits from overload and short circuit. It is a valuable tool for electricians and other electrical professionals.
Rated current: 50 A
Frame size: 125AF
Number of poles: 4
Trip unit: Thermal-magnetic
Breaking capacity: 50 kA
Rated voltage: 400/415 V
Frequency: 50/60 Hz
Insulation voltage: 800 V
Impulse withstand voltage: 8 kV
Mechanical life: 20,000 cycles
Electrical life: 7,500 cycles
Features: 1/3/5
Reliable: The breaker is made by a reputable manufacturer and has a long history of reliable operation.
Safe: The breaker is designed to protect electrical circuits from overload and short circuit.
Versatile: The breaker is available in a variety of ratings and configurations, making it suitable for a wide range of applications.
Easy to use: The breaker is easy to install and use.
Configurable delay time: The breaker can be configured with a delay time of 1/3/5 seconds, which makes it suitable for a variety of applications.
HDM3L-125F/4P(A)-mag-therm-50A is a thermal-magnetic circuit breaker with a rated current of 50 A and 4 poles. It is designed to protect electrical circuits from overload and short circuit. The breaker has a breaking capacity of 125 kA and a rated voltage of 400 V. It is also equipped with an earth leakage protection function and has a delay time of 1/3/5 seconds.
The delay time is the amount of time it takes for the breaker to trip after the current exceeds the rated current. The different delay times are used to protect different types of equipment and electrical circuits. For example, a short delay time is used to protect equipment that can withstand a brief overload, while a long delay time is used to protect equipment that is more sensitive to overload.
The HDM3L-125F/4P(A)-mag-therm-50A is a reliable and safe way to protect electrical circuits from overload and short circuit. It is a valuable tool for electricians and other electrical professionals.